Free shipping on UK orders over £100
We sell to all EU countries

3500 Ohm Single ended 10W Output transformer (KT88 or similar)

A high quality 10W Single ended output transformer. May be used in any single ended design with a valve having an output impedance of 3500 Ohms, such as a KT88.

Primary

90mA DC current
Multi section winding, for reduced leakage inductance.

Inductance

Inductance 24H at 25Hz.
Leakage inductance 15mH

Bandwidth

Wide bandwidth, 20-30KHz. (-1dB)

Secondary

Output impedance 4,8 and 16 Ohms.

Steel

High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.

Winding wire

Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Layer wound for excellent wind consistency and alignment resulting in reduced leakage inductance.

Connecting wire – stand up only

High quality PVC 600V
Primary : 24AWG UL1015
Secondary : 20 AWG UL1015

Mounting

Available in Frame, Drop through or stand up versions.

A very high quality 20W Single ended output transformer. Designed initially for single ended 300B amplifier but may be used in any single ended design with a valve having an output impedance of 3500 Ohms. A large design to enable good performance down to low frequencies. Designed for those that require a no-compromise single ended output amplifier.

Primary

100mA DC current
Multi section winding, for reduced leakage inductance.

Inductance

Inductance 24H.
Leakage inductance 13mH

Bandwidth

Exceptional bandwidth at full power.
Wide bandwidth, 15-30KHz. (-1dB)

Secondary

Output impedance 4,8 and 16 Ohms.

Steel

Highest quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.

Winding wire

Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Layer wound for excellent wind consistency and alignment resulting in reduced leakage inductance.

Connecting wire

High quality PVC 600V
Secondary : 20 AWG UL1015

Mounting

Available in Clamp drop through or Frame versions.

A very high quality 20W Single ended output transformer. May be used in any single ended design with a valve having an output impedance of 5000 Ohms. A large design to enable good performance down to low frequencies. Designed for those that require a no-compromise single ended output amplifier.

Primary

100mA DC current
Multi section winding, for reduced leakage inductance.

Inductance

Inductance 24H.
Leakage inductance 13mH

Bandwidth

Exceptional bandwidth at full power.
Wide bandwidth, 15-30KHz. (-1dB)

Secondary

Output impedance 4,8 and 16 Ohms.

Steel

Highest quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.

Winding wire

Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Layer wound for excellent wind consistency and alignment resulting in reduced leakage inductance.

Connecting wire

High quality PVC 600V
Secondary : 20 AWG UL1015

Mounting

Available in Clamp drop through or Frame versions.

A high quality 10W at 20Hz Push pull ultra linear output transformer. Designed for the Mullard 5-10 amplifier but may be used in any single ended design with a valve having an output impedance of 6600 Ohms anode to anode, such as an EL84.

Primary

Multi section winding, for reduced leakage inductance.

Inductance

Inductance 35H at 25Hz.
Leakage inductance 6mH

Bandwidth

Wide bandwidth, 10-50KHz. (-1dB)

Secondary

Output impedance 4,8 and 16 Ohms.

Steel

High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.

Winding wire

Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Layer wound for excellent wind consistency and alignment resulting in reduced leakage inductance.

Connecting wire – stand up only

High quality PVC 600V
Primary : 24AWG UL1015
Secondary : 20 AWG UL1015

Mounting

Frame, Drop through or stand up versions, all with flying leads.

Weight

1.6Kg

A high quality 10W at 20Hz Push pull ultra linear output transformer. Designed for the Mullard 5-10 amplifier but may be used in any single ended design with a valve having an output impedance of 8000 Ohms anode to anode, such as an EL84.

This is similar to our 6600 Ohm 20% ultra linear tap design, but results in an improvement in distortion of around 0.1% as described in the Mullard “Circuits for amplifiers” book.

Primary

Multi section winding, for reduced leakage inductance.

Inductance

Inductance 35H at 25Hz.
Leakage inductance 3mH

Bandwidth

Wide bandwidth, 10-50KHz. (-1dB)

Secondary

Output impedance 4,8 and 16 Ohms.

Steel

High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.

Winding wire

Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Layer wound for excellent wind consistency and alignment resulting in reduced leakage inductance.

Connecting wire – stand up only

High quality PVC 600V
Primary : 24AWG UL1015
Secondary : 20 AWG UL1015

Mounting

Frame, Drop through or stand up versions, all with flying leads.

Weight

1.6Kg

A high quality 3.5W Single ended output transformer. Designed for the Mullard 3-3 amplifier but may be used in any single ended design with a valve having an output impedance of 5000 Ohms, such as an EL84.

Primary

50mA DC current
Multi section winding, for reduced leakage inductance.

Inductance

Inductance 24H at 25Hz.
Leakage inductance 15mH

Bandwidth

Wide bandwidth, 20-30KHz. (-1dB)

Secondary

Output impedance 4,8 and 16 Ohms.

Steel

High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.

Winding wire

Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Layer wound for excellent wind consistency and alignment resulting in reduced leakage inductance.

Connecting wire – stand up only

High quality PVC 600V
Primary : 24AWG UL1015
Secondary : 20 AWG UL1015

Mounting

Available in Clamp, Frame, Drop through or stand up versions.

A superb quality mains transformer for any valve project. Originally designed to power a Mullard 5-10 Mono amplifier. It will happily power a stereo Mullard 3-3 amplifier alone, without the pre-amp.
Proudly made in the United Kingdom

Primaries

European primary voltages, 220V, 230V, 240V and 250V.
US primary dual 120V.

Secondaries

HT winding 300V – 0 – 300V at 100mA DC
Heater winding 6.3V at 2A centre tapped.
Rectifier winding 6.3V at 1A

Steel

High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.

Winding wire

Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.

Electrostatic Screen

Solid copper sheet providing the best RF screening possible between primary and secondaries.

Connecting wire

High quality PVC 600V
Primary and HT : 24AWG UL1015
Secondary LT : 20 AWG UL1015

Weight

2.3Kg

Compliance

Built and tested to safety standard BS EN 61558-1 2005

Designed to power a Mullard 5-10 Stereo amplifier using a single GZ34 or two EZ81 rectifiers.
Proudly made in the United Kingdom

Primaries

European primary voltages, 220V, 230V, 240V and 250V.

Secondaries

HT winding 300V – 0 – 300V at 200mA
Heater windings 6.3V at 4A centre tapped.

Rectifier winding 6.3V at 2A tapped at 5V at 2A.

Steel

High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.

Winding wire

Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.

Electrostatic Screen

Solid copper sheet providing the best RF screening possible between primary and secondaries.

Connecting wire

High quality PVC 600V
Primary and HT : 22AWG UL1015
Secondary LT : 20 AWG UL1015

Weight

3Kg

Compliance

Built and tested to safety standard BS EN 61558-1 2005

Designed to power a Mullard 5-20 Mono amplifier to the Mullard specification.
Proudly made in the United Kingdom

Primaries

European primary voltages, 220V, 230V, 240V and 250V.

Secondaries

HT winding 410V – 0 – 410V at 180mA DC
Heater windings 6.3V at 4A centre tapped, 6.3V at 2.5A centre tapped.
Rectifier winding 5V at 3A

Steel

High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.

Winding wire

Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.

Electrostatic Screen

Solid copper sheet providing the best RF screening possible between primary and secondaries.

Connecting wire

High quality PVC 600V
Primary and HT : 22AWG UL1015
Secondary LT : 20 AWG UL1015

Weight

3Kg

Compliance

Built and tested to safety standard BS EN 61558-1 2005

Consisting of our excellent 3-3 output transformer and our robust mono 3-3 mains transformer.

Provides the magnetic components for a new mono Mullard 3-3 build, at a reasonable price.

A superb quality mains transformer for any valve project. Originally designed to power a Mullard 3-3 Mono amplifier.
Proudly made in the United Kingdom

Primaries

European primary voltages, 220V, 230V, 240V and 250V.
US primary voltage dual 120V.

Secondaries

HT winding 300V – 0 – 300V at 80mA DC
Heater winding 6.3V at 1A centre tapped.
Rectifier winding 6.3V at 1A

Steel

High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.

Winding wire

Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.

Electrostatic Screen

Solid copper sheet providing the best RF screening possible between primary and secondaries.

Connecting wire – stand up only

High quality PVC 600V
Primary and HT : 24AWG UL1015
Secondary LT : 20 AWG UL1015

Weight

1.5Kg

Compliance

Built and tested to safety standard BS EN 61558-1 2005