A superb quality multipurpose transformer for any valve project or experimentation.
Proudly made in the United Kingdom
Primaries
European primary voltages, 220V, 230V, 240V and 250V.
Secondaries
A single 250V 100mA secondary for use with a silicon rectifier.
Heater winding 6.3V at 2A centre tapped.
Steel
High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.
Construction
Separate primary and secondary sections for safety.
Winding wire
Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Connecting wire – stand up only
High quality PVC 600V
Primary and HT : 24AWG UL1015
Secondary LT : 20 AWG UL1015
Weight
1Kg for the clamp version
Compliance
Built and tested to safety standard BS EN 61558-1 2005
A superb quality mains transformer for any valve project. Originally designed to power a Mullard 5-10 Mono amplifier. It will happily power a stereo Mullard 3-3 amplifier alone, without the pre-amp.
Proudly made in the United Kingdom
Primaries
European primary voltages, 220V, 230V, 240V and 250V.
US primary dual 120V.
Secondaries
HT winding 300V – 0 – 300V at 100mA DC
Heater winding 6.3V at 2A centre tapped.
Rectifier winding 6.3V at 1A
Steel
High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.
Winding wire
Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Electrostatic Screen
Solid copper sheet providing the best RF screening possible between primary and secondaries.
Connecting wire
High quality PVC 600V
Primary and HT : 24AWG UL1015
Secondary LT : 20 AWG UL1015
Weight
2.3Kg
Compliance
Built and tested to safety standard BS EN 61558-1 2005
Designed to power a Mullard 5-20 Mono amplifier to the Mullard specification.
Proudly made in the United Kingdom
Primaries
European primary voltages, 220V, 230V, 240V and 250V.
Secondaries
HT winding 410V – 0 – 410V at 180mA DC
Heater windings 6.3V at 4A centre tapped, 6.3V at 2.5A centre tapped.
Rectifier winding 5V at 3A
Steel
High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.
Winding wire
Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Electrostatic Screen
Solid copper sheet providing the best RF screening possible between primary and secondaries.
Connecting wire
High quality PVC 600V
Primary and HT : 22AWG UL1015
Secondary LT : 20 AWG UL1015
Weight
3Kg
Compliance
Built and tested to safety standard BS EN 61558-1 2005
A superb quality mains transformer for any valve project. Originally designed to power a Mullard 3-3 Mono amplifier.
Proudly made in the United Kingdom
Primaries
European primary voltages, 220V, 230V, 240V and 250V.
US primary voltage dual 120V.
Secondaries
HT winding 300V – 0 – 300V at 80mA DC
Heater winding 6.3V at 1A centre tapped.
Rectifier winding 6.3V at 1A
Steel
High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.
Winding wire
Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Electrostatic Screen
Solid copper sheet providing the best RF screening possible between primary and secondaries.
Connecting wire – stand up only
High quality PVC 600V
Primary and HT : 24AWG UL1015
Secondary LT : 20 AWG UL1015
Weight
1.5Kg
Compliance
Built and tested to safety standard BS EN 61558-1 2005
A superb quality mains transformer for any valve project or experiment.
Proudly made in the United Kingdom
Primaries
European primary voltages, 220V, 230V, 240V and 250V.
Secondaries
HT windings 2 separate 0 – 250V @ 80mA These may be connected in series to give 250 – 0 – 250V @ 80mA or parallel to give 0 – 250V @ 160mA
Heater winding 6.3V at 2A centre tapped.
Rectifier winding 5V at 2A
https://primarywindings.com/2020/12/21/the-very-versatile-pwht01-and-pwht02-transformer/
Steel
High quality 400-50 silicon steel.
Hand laminated for the best stacking factor, and accuracy.
Winding wire
Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Weight
1.4Kg
Compliance
Built and tested to safety standard BS EN 61558-1 2005
A superb quality mains transformer for any valve project or experiment.
Proudly made in the United Kingdom
Primaries
European primary voltages, 220V, 230V, 240V and 250V.
Secondaries
HT windings 2 separate 0 – 250V @ 80mA These may be connected in series to give 250 – 0 – 250V @ 80mA or parallel to give 0 – 250V @ 160mA
Heater winding 6.3V at 2A centre tapped.
Rectifier winding 6.3V at 2A
Heater windings in parallel can give 6.3V @ 4A
https://primarywindings.com/2020/12/21/the-very-versatile-pwht01-and-pwht02-transformer/
Steel
High quality 400-50 silicon steel.
Hand laminated for the best stacking factor, and accuracy.
Winding wire
Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Weight
1.4Kg
Compliance
Built and tested to safety standard BS EN 61558-1 2005
A superb quality mains transformer for any valve project.
Proudly made in the United Kingdom
Primaries
European primary voltages, 220V, 230V, 240V and 250V.
Secondaries
HT winding 300V at 320mA DC
Heater winding 6.3V at 3A centre tapped.
Steel
High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.
Winding wire
Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Connecting wire – stand up only
High quality PVC 600V
Primary and HT : 24AWG UL1015
Secondary LT : 20 AWG UL1015
Weight
2.07Kg
Compliance
Built and tested to safety standard BS EN 61558-1 2005
This transformer was inspired by the EAR 834P RIAA pre-amplifier, but may be used in many other designs.
Proudly made in the United Kingdom
Primaries
European primary voltages, 220V, 230V, 240V and 250V.
Secondaries
A single 250V 80mA secondary for use with a silicon rectifier.
Heater winding 6.3V at 2A centre tapped.
Steel
High quality Grain Orientated M6 0.35mm.
Hand laminated for the best stacking factor, and accuracy.
Construction
Separate primary and secondary sections for safety.
Winding wire
Double coated Grade 2 enamelled copper wire.
Wound using CNC winders for highly accurate wire placement and turns count.
Connecting wire – stand up only
High quality PVC 600V
Primary and HT : 24AWG UL1015
Secondary LT : 20 AWG UL1015
Weight
1Kg
Compliance
Built and tested to safety standard BS EN 61558-1 2005
Part of the PWHT2000 series mains transformers
Primaries:
European: 220V – 250V in 10V steps.
Secondaries:
- S1: 500V CT (250V – 0 – 250V) @ 100mA
- S2: 6.3V CT @ 1A
- S3: 5V @ 2A
Screen:
Solid copper screen between the primary and secondary. For superior safety and reduction in EMI conduction from primary to secondary.
Wires:
18 AWG Alpha wire 15 ” lead length.
Part of the PWHT2000 series mains transformers
Primaries:
European: 220V – 250V in 10V steps.
Secondaries:
- S1: 550V CT (275V – 0 – 275V) @ 200mA
- S2: 6.3V @ 6A
- S3: 5V @ 3A
Screen:
Solid copper screen between the primary and secondary. For superior safety and reduction in EMI conduction from primary to secondary.
Wires:
18 AWG Alpha wire 15 ” lead length.
Part of the PWHT2000 series mains transformers
Primaries:
European: 220V – 250V in 10V steps.
Secondaries:
- S1: 600V CT (300V – 0 – 300V) @ 200mA
- S2: 6.3V @ 4A
- S3: 5V @ 3A
Screen:
Solid copper screen between the primary and secondary. For superior safety and reduction in EMI conduction from primary to secondary.
Wires:
18 AWG Alpha wire 15 ” lead length.
Part of the PWHT2000 series mains transformers
Primaries:
European: 220V – 250V in 10V steps.
Secondaries:
- S1: 750V CT (375V – 0 – 375V) @ 175mA
- S2: 6.3V CT @ 6A
- S3: 5V CT @ 3A
Screen:
Solid copper screen between the primary and secondary. For superior safety and reduction in EMI conduction from primary to secondary.
Wires:
18 AWG Alpha wire 15 ” lead length.
Part of the PWHT2000 series mains transformers
Primaries:
European: 220V – 250V in 10V steps.
Secondaries:
- S1: 350V CT (175V – 0 – 175V) @ 100mA
- S2: 6.3V CT @ 2A
- S3: 5V @ 2A
Screen:
Solid copper screen between the primary and secondary. For superior safety and reduction in EMI conduction from primary to secondary.
Wires:
18 AWG Alpha wire 15 ” lead length.
Part of the PWHT2000 series mains transformers
Primaries:
European: 220V – 250V in 10V steps.
Secondaries:
- S1: 510V CT (255V – 0 – 255V) @ 125mA
- S2: 6.3V CT @ 4A
Screen:
Solid copper screen between the primary and secondary. For superior safety and reduction in EMI conduction from primary to secondary.
Wires:
18 AWG Alpha wire 15 ” lead length.
Part of the PWHT2000 series mains transformers
Primaries:
European: 220V – 250V in 10V steps.
Secondaries:
- S1: 600V CT (300V – 0 – 300V) @ 75mA
- S2: 6.3V CT @ 3A
- S3: 5V CT @ 2A
Screen:
Solid copper screen between the primary and secondary. For superior safety and reduction in EMI conduction from primary to secondary.
Wires:
18 AWG Alpha wire 15 ” lead length.
Part of the PWHT2000 series mains transformers
Primaries:
European: 220V – 250V in 10V steps.
Secondaries:
- S1: 290V @ 25-0mA
- S2: 6.3V CT @ 4A
Screen:
Solid copper screen between the primary and secondary. For superior safety and reduction in EMI conduction from primary to secondary.
Wires:
18 AWG Alpha wire 15 ” lead length.